Faster Tender
OpenSources Sought

BOILER SAFETY DEVICE TESTING SERVICES

261-NETWORK CONTRACT OFFICE 21 (36C261)VETERANS AFFAIRS, DEPARTMENT OF / VETERANS AFFAIRS, DEPARTMENT OF / 261-NETWORK CONTRACT OFFICE 21 (36C261)

AI quick read

Get a plain-English summary, the key facts a bidder needs, and who it's a fit for.

Posted
Jun 3, 2026
Response deadline
Jun 10, 2026, 7:00 PM EDT
Due in 4 days
Value
Category
HVAC / Plumbing
NAICS
238220
PSC / Class
H299
Set-aside
Place of performance
California
Solicitation #
36C26126Q0778
Archive date
Jun 25, 2026

Search tags

Market context

Open in NAICS 238220
299
13 in California
Typical award (NAICS)
$266,574
median of 69 awards
Recent winners
3

Description

The Department of Veterans Affairs (VA) is conducting market research to identify qualified firms capable of providing Boiler Safety Device Testing Services in support of the VA Central California Health Care System (VACCHCS) Central Energy Plant located in Fresno, California. The Government is specifically seeking information regarding contractor capability, experience, geographic availability, and business size status to assist in determining the most appropriate acquisition strategy for this requirement. The Government anticipates a Firm-Fixed-Price (FFP) services contract for Boiler Safety Device Testing Services. The contractor shall provide all labor, supervision, management, tools, testing equipment, transportation, permits, personal protective equipment (PPE), and qualified personnel necessary to perform recurring inspection and testing services for boiler plant equipment, pressure vessel inspections, and Boiler External Inspection (BEI) safety devices located within the Central Energy Plant. Services are anticipated to include: � Monthly boiler safety device testing activities � One Government-scheduled semiannual boiler safety device inspection/testing cycle per contract year � Boiler pressure vessel inspection support � Boiler External Inspection (BEI) safety device testing � Completion of Government-provided testing checklists � Deficiency identification and reporting � Inspection and testing documentation This requirement is for inspection and testing services only. The contractor shall not perform repairs, corrective maintenance, equipment replacement, valve replacement, system modifications, or warranty work under this requirement. The contractor shall perform services in accordance with: � VHA Directive 1810 � VHA Boiler and Associated Plant Safety Device Testing Manual � Government-provided testing checklists � Applicable manufacturer recommendations � OSHA requirements � Federal, State, and local regulations